Tension and Compression Load Cell CTS01

The CTS01 stainless steel load cell has been designed to accurately measure small dynamic and static forces from 10 kN. Due to the applied design principle, the measurement errors remain negligible even with strongly eccentric forces.

Technical Data

Nominal force [kN]10, 20 kN
Max. operating force [% Fnom]160 %
Absolute max. force [% Fnom)1000 %
Combined error0,5 %
Max. bridge supply voltage10 V DC


Scope of Supply

Tension and compression load cell in flat design with 5 m cable (PVC) and connection T: cable gland, straight

Further connection variant:
N2:  plug connection, M12 molded onto PUR cable

for example:

CTS02

Flat ring sensor, insensitive to excentric load application

Nominal force range 150 ... 300 kN
Material: stainless steel
 

RKS01

Flat sensor for precise measuring in several designs and dimensions

Nominal force range 1 ... 200 kN
Material: stainless steel
 

RKS02

Robust ring force sensor for large forces

Nominal force range 1 ... 10 MN
Material: Stainless steel

 

for example:

DMA

Easily operated amplifier, easy commissioning,
operation with keyboard input.

Signal outputs: -10... +10 V/V  /  4...20 mA  /  0...20 mA
Total amplification range: 250... 4000 V/V

MV125

Reliable, precise amplifier in the field housing

Signal outputs: -10... +10 V/V  /  4...20 mA  /  0...20 mA
Total amplification range: 400... 3200 V/V

AME2

Easy to use, cost-effective amplifier for DIN rail mounting

Signal outputs: -10... +10 V/V / 4...20 mA  /  0...20 mA
Total amplification range: 400... 3200 V/V

Fieldbus Amplifiers

• Digital and analog
• Field mounting and DIN rail

• Profibus
• Profinet
• EtherNet/IP
• DeviceNet
• CANopen